HPE MSA monitoring with Topologix

Infrastructure & Networking

One integration per HPE MSA 2050 or 2060 array (the 1060 and 2062 answer the same API), read over the array’s HTTPS API with a monitor-role user: controllers, enclosures, disks, disk groups, pools, volumes, host ports, sensors, power supplies and fans, the event log and the performance counters. Every few hours the volumes, hosts, host groups and mappings are read too, so a volume is linked to the VMware datastore it backs.

Requirements

  • An MSA user with the monitor role and the WBI / API interface enabled. Every request is a show command; nothing is ever changed on the array.
  • HTTPS reach to a controller’s management address (port 443) from the server or a proxy agent (proxy 1.361.0 or later). Verify TLS certificate can be turned off for the array’s self-signed certificate.
  • The array allows only a few concurrent sessions: every read logs in, runs its commands and logs out (exit) at the end, also after an error.

1 · Set up the integration

  1. Open the Integrations pageClick Integrations in the toolbar and pick HPE MSA from the catalogue.
  2. Enter the array and the accountThe Management address of a controller (https://msa-a.example.com or just the address), the Username and Password of the monitor user. The password is sealed at rest.
  3. Pick the topology cadenceStorage topology read sets how often the volumes, hosts and mappings are read — every 1–6 hours (default 3 h) or off.
  4. Create, then verifyClick Create, reopen the integration and click Test. It logs in (the hashed login first, then Basic authentication on 2060 firmware), reads the system name, product and health, and logs out.
Target on a private network? Route it through a proxy agent. Proxy agents run inside your network — behind NAT, on a management VLAN, in an air-gapped segment — and reach targets the Topologix server can't. The agent polls the server every 15 seconds for its assignments, runs the checks locally, and pushes results back every 5 seconds, so no inbound firewall rules are ever needed. Set a default proxy on the integration; every metric source can override it. If a proxy goes offline, its sources are marked stale within ~90 seconds and the last known values stay visible.

2 · Add it to a flow

  1. Select the storage nodeClick the node, open Metrics, then + Add and choose the HPE MSA integration.
  2. Adjust the settingsPool used % (default 85) and the Event window (default 24 h, 1–168). Each shows the value in effect and where it comes from.
  3. SaveSet the interval and click Add Source. On a Datacenter rack device the source supplies the product, its serial number, the enclosures’ power draw and the hottest sensor.
Live canvas screenshots for this integration require a real HPE MSA environment, so this guide shows the configuration screens only — the flow steps above work exactly like every other integration.

3 · What raises an alert

These rules are always on.

Red

A controller, disk, power supply or fan whose health is Degraded or Fault, a critical sensor, a degraded disk group, a host port that was up on an earlier poll and is not up now, and events of severity CRITICAL.

Amber

A disk group reconstructing, a sensor at Warning, a pool over its threshold, and events of severity ERROR or WARNING in the window. Each event’s text goes through the organisation’s log redaction rules.

A volume’s WWN (600C0FF0…) is the naa.600c0ff… device name ESXi shows.

A VMFS datastore whose extent has exactly that identifier is linked to the volume. A volume with no WWN on its firmware is listed but not linked — the identifier is never derived.

Hosts and host groups (with their FC WWPNs and iSCSI IQNs) and the volume mappings name the hosts that see a volume. A default mapping to “all other initiators” names no host and is not linked.

Good to know

  • The JSON API is used when the firmware offers it, otherwise the XML API; both give the same figures.
  • IOPS and MB/s are the change of the controllers’ read / write counters between two polls (the first poll uses the array’s own rates); the response time is the host ports’ average, converted from microseconds.
  • “Down that was up” remembers the ports seen up since the server or proxy last started.
  • A command the firmware does not know becomes a note on the source. Only a refused login fails the read, naming the monitor role.

All integrations →

See it on your own infrastructure

Book a demo and we will walk you through Topologix with your systems in mind: on our cloud, or self-hosted in your own network.